Categories | Pneumatic Solenoid Valve |
---|---|
Brand Name: | Brando |
Model Number: | 4V230C-06 |
Certification: | CE |
Place of Origin: | CHINA |
MOQ: | 2 sets |
Price: | negotiation |
Payment Terms: | L/C, T/T, Western Union,Paypal |
Supply Ability: | 25000 sets per week |
Delivery Time: | 4-7 days |
Packaging Details: | Inner Box,Carton,Pallet |
Port size: | 1/8" 1/4" 3/8" |
Power: | Pneumatic |
Structure: | Pilot |
Pressure: | 0~8 bars |
Temperature of media: | -5~60℃ |
Media: | Air |
Application: | Automation Equipment |
Type: | Normally close |
Body material: | Aluminum Alloy |
Operating temperature: | NBR for -5~80℃ and VITON for -5~150℃ |
4V230C-06 5/2 Double Electro Solenoid Valve For Pneumatic DC 12 24 Volt AC 220 Volt
4V230C-06 pneumatic cylinder valve is an industrial device that is controlled by electromagnetic force. It is an automatic basic component for controlling fluid. It is an actuator, and a pneumatic solenoid valve is one of them. It controls the movement of the piston to block or leak different holes. The hole is normally open, the gas will enter different outlet pipes, and then the piston of the cylinder will be pushed by the pressure of the pneumatic electromagnetic valve, so that the mechanical movement of the entire solenoid valve is controlled by the current of the electromagnet controlling the pneumatic solenoid valve.
The combination of 4V pneumatic solenoid valve technology and control technology, computer technology, and electronic technology has enabled a variety of complex controls. For example, the 4V pneumatic solenoid valve can be applied in the field of intelligent control and applied in wireless control technology. Because the 4V pneumatic solenoid valve can be controlled by electromagnetic, it can interface well with various electronic systems, which is one of the main reasons for its wide application.
Technical information chart 4V230C-06 High Speed Double Coils Solenoid Valve For Pneumatic:
Model | 4V210-08 | 4V220-08 | 4V230C-08 | 4V230E-08 | 4V230P-08 |
Coil and places | Single head Double position | Double head Double Position | Double head Three position close type | Double head Three position exhaust type | Double head Three position pressure type |
Position number | two position five ways | three position five ways | |||
Working medium | 40 μm filtered clean air | ||||
Wiring type | Brown or Transparent with lighting connector type | ||||
Highest action frequency | 5 times per sec | ||||
Shortest action time | 0.05 sec |
Piston and seals of 4V230C-06 pneumatic solenoid valve 5/2 24V:
Laser engraving information of 4V series pneuamtic solenoid valve in pneumatic:
Actual use display of 4V solenoid valve for pneumatic cylinder:
Principle of 4V pneumatic control electromagnetic valve on
automatic control equipment:
For small automatic control equipment, the gas pipe is generally
8~12mm industrial rubber pipe. Electrically speaking, the
two-position three-way solenoid valve is generally a single
electronic control (ie, a single coil), and the two-position
five-way solenoid valve is generally a dual electronic control (ie,
a double coil). The coil voltage level is generally DC24V, AC220V,
etc.
The two-way three-way solenoid valve is divided into two types:
normally closed type and normally open type. The normally closed
type means that the gas path is broken when the coil is not
energized, and the normally open type means that the gas path is
open when the coil is not energized. Normally closed two-way
three-way solenoid valve operating principle: the coil is
energized, the gas path is connected, and once the coil is
de-energized, the gas path will be disconnected. Normally open
two-position three-way single electronically controlled solenoid
valve action principle: the coil is energized, the gas path is
disconnected, and once the coil is de-energized, the gas path will
be connected.
The operation principle of the two-way five-way double
electronically controlled solenoid valve: when the positive action
coil is energized, the positive action air path is turned on (the
positive action air outlet has gas), even if the positive action
coil is powered off, the positive action air path is still
connected. It will be maintained until the counter-action coil is
energized. When the reverse action coil is energized, the reverse
action air path is turned on (the reverse action air hole has gas),
and even if the reverse action coil is turned off, the reverse
action air path is still turned on, and will continue until the
positive action coil is energized. . Based on the characteristics
of the two-way five-way dual electronically controlled solenoid
valve, when designing the electromechanical control loop or
programming the PLC program, the solenoid valve coil can be
operated for 1~2 seconds, which can protect the solenoid valve coil
from being easily damaged.