Hole Size: | 11mm |
Height: | 36mm |
Width: | 38.5mm |
Voltage: | 24V AC |
Power: | 20VA |
Connector: | DIN43650A |
Insulation Class: | H |
Enameled Wire Material: | Copper |
Suitable Valve Number: | SCG353A043, SCG353A044, SCG353A051 |
400325-101 24VAC Pneumatic Solenoid Coil For ASCO Type SCG353A043 SCG353A044 SCG353A051 Pulse Jet Valve
Coils are electrical devices that produce magnetic flux when electrical power is applied to the windings. Surrounding the coil is the metal solenoid enclosure and frame. Together with the plunger and stop, it forms the magnetic circuit that operates the valve. Without the enclosure, the magnetic circuit is not complete. Without a complete magnetic circuit, the magnetic field is reduced and valve performance suffers. Depending on the coil voltage and power rating, the pressure rating of the valve can vary.
Model number | BB11036001 |
Ref number | 400325642, 400325101, 400325118 |
Normal voltage | AC110V, AC220V, DC12V, DC24V (Other can be customized) |
Normal power | AC:20VA, DC: 21Watt |
Material | BMC, Brass |
Wire class | H |
Connection | DIN43650A |
Application | ASCO SCG353A043, SCG353053 Pulse Valve |
Hole diameter | 11 mm |
Height | 36 mm |
Width | 38.5 mm |
Valve Model | Repair Kits | Solenoid Coils | ||||
AC | DC | 24VDC | 24 VAC | 110VAC | 220VAC | |
SCG353A043 | C113444 | C113444 | 400325642 | 400325101 | 400325118 | 400325118 |
ACG353AD44 | C113444 | C113444 | 400325642 | 400325101 | 400325118 | 400325118 |
ACG353052 | C113444 | C113444 | 400325642 | 400325101 | 400325118 | 400325118 |
SCG353053 | C113444 | C113444 | 400325642 | 400325101 | 400325118 | 400325118 |
SCG353AD47 | C113827 | C113827 | 400425342 | 400425101 | 400425118 | 400425117 |
SCG353050 | C113685 | C113686 | 400425342 | 400425101 | 400425118 | 400425117 |
SCG353051 | C113685 | C113686 | 400425342 | 400425101 | 400425118 | 400425117 |
SCG353060 | C123432 | C123433 | 400425342 | 400425101 | 400425118 | 400425117 |
SCG353AD65 | C113827 | C113827 | 400425342 | 400425101 | 400425118 | 400425117 |
Main Dimension of 400325-142 ASCO Type Pulse Valve Coil:
Coil Failure:
1.Overvoltage
Check voltage at coil. Voltage must conform to nameplate rating.
2.Damaged core or core tube causing inrush current to be drawn continuously./Excessive foreign matter jamming core in core tube.
Check for damaged core and core tube, or damaged spring. Check for scale or foreign matter on the core or inside the core tube. Clean thoroughly and replace any damaged parts (contact us).
3.Excessive fluid pressure
Excessive fluid pressure Reduce pressure or install suitable valve.
4.Missing solenoid parts
Install missing coil or housing and other metal parts or properly install incorrectly assembled metal parts. The metal parts and housing (if used) form part of the magnetic circuit and are required to provide the impedance needed to limit current draw
Product Characteristic:
1. Using high quality wire which has UL approved;
2. Using high quality permeablity magnetic material which contain
low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and
so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof
coils and so on.
7. If you have special requirement, pls feel free to contact us.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!