Categories | RO Water Treatment System |
---|---|
Brand Name: | Jufu |
Model Number: | JFRO-2000L |
Certification: | ISO9001 |
Place of Origin: | China |
MOQ: | 1 unit |
Price: | Negotiable |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Delivery Time: | 2-4 weeks |
Packaging Details: | Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping. |
Host Size: | 2700x600x1600mm (can be customized) |
Power: | 3KW |
Power Supply: | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure: | 0.8-1.2MPa |
Designed Water Inlet: | 3000L/h |
Outlet Flow: | 2000L/h |
Desalination rate: | ≥99.5% |
Raw Water Pump: | CNP/NYP/GRUNDFOS (Optional) |
Membrane size: | 4040 |
Number of Membranes: | 8 |
Membrane elements: | DOW/Hydranautics/Troy/Vontron (optional) |
Control valve: | Manual/Automatic |
Control Valve Brand: | FLECK/RUNXIN |
Tank Material: | SS/FRP (Optional) |
Pipe Material: | U-PVC, Stainless steel (Optional) |
2000LPH Reverse Osmosis System Water Purifying Machine Water
Purification Equipment
Product Introduction of RO Water Treatment System
Water treatment system treat raw water in several procedures in
order to meet the bottled drinking water standard.
This system uses water pressure pump to increase the water supply
pressure; sand filter is used to remove Plankton, Moss, Suspension,
Colloid and so on. Active carbon filter is used to remove strange
smell, chlorine, chloride, organic matter and heavy mental, lower
color and optimize water quality. Sodium softer is used to remove
the calcium and magnesium ions in water. Micro filter is used to
remove the tiny impurity. Hollow fiber Ultra filter can remove
impurity, colloid, phenolic compounds, chloride, germ and all the
harmful substance, meanwhile keep all beneficial minerals in water.
Reverse osmosis can move all the things in the water and to make
raw water to be pure water.
The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to
a pressure of 6-20 kg, the raw water permeates through the reverse
osmosis membrane with a pore size of only 0.0001 microns under the
action of pressure. Chemical ions, bacteria, fungi, and virions
cannot pass through, and are discharged with wastewater. Only water
molecules and solvents with a volume of less than 0.0001 microns
are allowed to pass through.
Technical Specifications of RO Water Treatment System
2000LPH Reverse Osmosis System | |
Model | JFRO-2000L |
Host Size | 2700x600x1600mm (can be customized) |
Power | 3KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 67% |
Designed Water Inlet | 3000L/h |
Outlet Flow | 2000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 8 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP |
Number of Membrane housing | 4 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method,
which has many advantages.
1) Non-phase-change physical method was used to desalinate and
purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can
remove colloid, organics, bacteria, virus and all kinds of heavy
metals in water at the same time.
3) With water pressure as the driving force, energy consumption is
the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination
of chemical waste liquid, no environmental pollution, and the
recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with
automatic protection function.
6) The system is simple, easy to operate, and the water quality is
stable.
7) Equipment covers small area, compact structure, reliable
operation and high water quality.
Process flow of RO Water Treatment System
Raw water pump→ mechanical filter(quartz sand filter)→ activated
carbon filter→ Water softener filter→security filter→ high pressure
pump →reverse osmosis system
1. Water tank: storage of tap water, to solve the problem of
insufficient tap water pressure and the back booster pump due to
the impact of insufficient water, reduce the failure rate
2. Booster pump: equipped with a stainless steel pump, to provide
sufficient pressure for subsequent filtration
3. Quartz sand filter: mainly remove the mud, suspended solids and
large particles in the tap water
4. Carbon filter: mainly remove organic substances, residual
chlorine and odor in tap water
5. Water softener filter: mainly remove the calcium and magnesium
in tap water, reduce the hardness of water
6. Security filter: further filtration, protection of reverse
osmosis membrane
7. High pressure pump: provide enough pressure for reverse osmosis
system
8. Reverse osmosis unit: the core part of pure water equipment, the
production of high-purity water.
9. Pure water tank: storage pure water, can change the size of the
water tank,after the below process,The water result is pure enough
for different application.
Photos of reverse osmosis water treatment system
FAQ:
1. What is the design water yield of ro membrane element? (except
anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3.What are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and
softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean
source, etc.
![]() |