Brand Name: Kacise
Model Number: KCS551
Place of Origin: shanxi xi'an
MOQ: 1
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Delivery Time: 5 work days
Packaging Details: each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature: -20-80℃
Operating Temperature: -20-60℃
Operating Humidity: 0-90%RH
Work Pressure: 0.8-1.2 atm
Supply Voltage: 12V
Maximum Operating Current: 100-150mA
T90: 5S
Repeatability of Zero: <±50 ppm
Repeatability of 50% FS: <±5% of the measured value
Life Span: 10 year
  • Product Details
  • Company Profile

Infrared CO2 Gas Sensor Module Carbon Dioxide Sensor Module


KCS551 Infrared CO2 Gas Sensor Module


1. overview

KCS551 is a gas detection module based on the principle of NDIR infrared absorption, which is suitable for detecting the concentration of carbon dioxide in a gaseous environment at room temperature.

KCS551 adopts a patented optical cavity, imported light source and dual-channel detector to realize the reference compensation of dual optical paths in space. KCS551 has good selectivity, no oxygen dependence and long life.

KCS551 has UART, IIC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose the application; The KCS551 provides zero point calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of sensor modules using outdoor free-flowing clean air. KCS551 adopts diffusion ventilation method, which has a fast diffusion speed.

KCS551 can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automotive and other applications. It can also be applied to other confined spaces for air quality monitoring.


2. Technical parameters


parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-2060°C
Operating HumidityHA090% RH
Work PressurePA0.81.2atm
Supply VoltageVs111230V
Maximum Operating CurrentImax100120150mA
T90Pump suction-5second
Repeatabilityzero<±50ppm
50% FS-<± 2% of the measured value-
Life Span10year

3.Structural dimension drawing

Unit: mm



Diffusion


Pump-suction type


4.Installation instructions

The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm

The wiring socket spacing is 2.54 m m

Note: SW400PV3.01, mounting aperture: 3.2mm


5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

6. Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Sensor range

3) Sensor measurement accuracy such as SW400, 0-2000pp


7. Order Information


Order information sheet
KCS551KCS551 CO2 concentration sensor
xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KCS551-2000-S-38400-Modbus-RTU

8. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


Appendix


ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

Quality Infrared CO2 Gas Sensor Module Carbon Dioxide Sensor Module for sale
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
Company Info
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly