Home > Action Figure >

Calibrated IEC60432-1 Figure C.1 and IEC60560-2 Figure 4 Torque Gauges for Torsion Resistance of B15 Unused Lamps

Categories Lampholder and Lampcap Gauges
Brand Name: PEGO
Model Number: PG-TB15
Certification: CNAS Calibration Certificate
Place of Origin: China
MOQ: 1 piece
Price: USD280-USD700
Payment Terms: Western Union, T/T, MoneyGram
Supply Ability: 10000sets/year
Delivery Time: 15 work days
Packaging Details: Each in a black gift box then into a carton box
Standard: IEC60432-1 and IEC60560-2
Type: B15
Material: Steel
Warranty: 1 Year
Service: OEM/ODM
  • Product Details
  • Company Profile

Calibrated IEC60432-1 Figure C.1 and IEC60560-2 Figure 4 Torque Gauges for Torsion Resistance of B15 Unused Lamps

Calibrated IEC60432-1 Figure C.1 and IEC60560-2 Figure 4 Torque Gauges for Torsion Resistance of B15 Unused Lamps

B15 Torque Gauge is met the requirements of IEC60432-1 figure C.1 and IEC60560-2 figure 4

DimensionB15 (mm)B22 (mm)Tolerance (mm)
A15.2722.27+0.03
B19.019.0Min.
C21.028.0Min.
D9.59.5Min.
E3.03.0+0.17
G18.324.6±0.3
H9.012.15Min.
K12.712.7±0.3
R1.51.5Approximate

Relative Gauges of IEC60061-3 B15 lamp Cap and holder Gauge

B15 Lamp Cap Gauge
7006-4A-2B15 Lamp Cap and holder GO and Not Go Gauges
7006-4B-1Gauges for testing the retention of B15d and B22d caps in the holder
7006-10-8Not Go gauges for caps on finished lamps BA9, B15, B22 and BY22d
7006-11-8Go gauges for caps on finished lamps BA9, B15, BA15 and B22
B15 Lampholder Gauge
7006-12C-21)Supplementary “Go” Gauge for lampholders B15
7006-12D-2“Not Go”/Retention Gauge for Lampholders B15
7006-15B-1Gauges for Checking Contact Position and Contact Force in Bayonet Lampholders B15d

1)Gauges for testing the insertion of caps in lamphoder B15d, B22d and BY22d (Figure No.: 7006-4A-2)

Purpose: to check B15d, B22d and BY22d cap dimensions for insertion of the cap on finished lamp in the lampholder.

2)Gauges for testing the retention of B15d and B22d caps in the holder (7006-4B-1)

Purpose: to check cap dimension for retention of the cap on the finished lamp in the lampholder.

3)Not Go gauges for caps on finished lamps BA9, B15, B22 and BY22d (7006-10-8)

Purpose: to check dimension A min. of caps BA9, B15, B22 and BY22d on finished lamps respectively.

4)Go gauges for caps on finished lamps BA9, B15, BA15 and B22 (7006-11-8)

Purpose: to check dimensions A max, N min, D1 min, D1 max, and the diametrical positions of the pins of caps BA9, B15, BA15 and B22 on finished lamps.

B15 Lampholder Gauge

1)Supplementary “Go” Gauge for lampholders B15 (7006-12C-2)

Purpose: The gauge shall be used solely to check interchangeability with respect to the corresponding caps on finished lamps after the test of clause 18: General resistance to heat, of IEC61184: Bayonet lampholders.

Testing: It shall be possible to inset the gauge into the holder and to locate the pins at the resting points without using undue force.

  1. “Not Go”/Retention Gauge for Lampholders B15 (7006-12D-2)

Purpose: The use of this gauge is restricted to the following purposes:

  1. To check the maximum internal diameter, dimension A, of lampholders of “all-ceramic” construction according to sheet 7005-16 with respect to maintaining retention of caps by both pins and to restricting angular displacement of lamps.
  2. To check the maximum internal diameter, dimension A, of lampholders according to sheet 7006-16 with respect to maintaining retention of caps by both pins and to restricting angular displacement of lamps, after the test of clause 18: General resistance to heat, of IEC61184: Bayonet lampholders.

Testing:

  1. With its axis parallel to the axis of the lampholder, it shall not be possible to insert the gauge (including the pin) into the bore of the lampholder other than at the “J” slots or at other points where it is not intended that the lamp cap should be supported.
  2. The gauge shall be inserted into the bore of the lampholder with the pin in one of the “J” slots and turned until the pin is seated at appropriate resting point. The gauge then is displayed laterally away from the direction of the pin as far as it will go in order to reduce retention to a minimum.

In this position it shall not be possible to remove the gauge when an axial pull is applied to it. The test is repeated at the other “J” slot.

4)Gauges for Checking Contact Position and Contact Force in Bayonet Lampholders B15d (7006-15B-1)

Purpose: To check lampholders B15d with respect to:

  • Dimension Dmax.
  • The minimum and maximum forces of the individual contacts corresponding with those resulting from the fitting of caps B15d of which the values of dimension D1 are minimum and maximum respectively.


Quality Calibrated IEC60432-1 Figure C.1 and IEC60560-2 Figure 4 Torque Gauges for Torsion Resistance of B15 Unused Lamps for sale
Send your message to this supplier
 
*From:
*To: Pego Group (HK) Company Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly