Brand Name: XL
Model Number: XL-9200
Certification: CE
Place of Origin: China
MOQ: negotiate
Price: negotiate
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 800 pcs per month
Delivery Time: 3~4 weeks
Packaging Details: external packing:carton or non wooden box;cushion packing:EPE foam
Name: Electrical Calibration Equipment
Accuracy level: 0.02%
Voltage: 0-1000V
power error: 0.1%
AC frequency range: 0.001-5KHz
stability: better than 0.01%
  • Product Details
  • Company Profile

High Accuracy Electrical Calibration Equipment For For DC Energy Meter Verification

High Accuracy Electrical Calibration Equipment For For DC Energy Meter Verification


XL-9200 DC electric energy meter verification device is the latest standard voltage and current source designed and developed by Shenzhen Xinglong Technology Co., Ltd., which is based on the current national standard for DC energy meter verification and adopts the latest technology. The main components are imported industrial grade devices, which can support 0~200ADC high current signal, the accuracy level is better than 0.05%; 0~1000V DC voltage output, accuracy grade is better than 0.02%; 0~5V DC voltage analog shunt Output, accuracy class 0.05%, and support voltage, current output ripple superposition function, can be used for DC load meter virtual load verification, ripple interference test, or as a separate voltage standard source, current standard source, power standard source The device has passed the test of Shenzhen Metrology Institute.
The device adopts 800×600 liquid crystal display, the interface is clear and simple, the operation is convenient, and the visual effect is good. The core module uses 32-bit high-speed DSP combined with adaptive Lagrangian interpolation algorithm to eliminate the hardware non-synchronization error of DC ripple. Waveform quantization uses 32-bit dual modulation output technology to ensure high output accuracy. The output has overcurrent and overheat protection, which is safe and reliable.


Name:Electrical Calibration EquipmentAccuracy Level:0.02%
Voltage:0-1000VPower Error:0.1%
AC Frequency Range:0.001-5KHzStability:Better Than 0.01%

1.Main functions


Main function Description
DC voltage output Supports 0~1000V DC voltage output with an accuracy of up to two ten thousandths
DC current output Supports 0~250A DC current output with accuracy up to five ten thousandths
Small signal output Supports 0~5V DC voltage output with accuracy better than 5/10,000
Ripple output supports 20~500Hz ripple output
DC electric energy meter verification Supports virtual load meter verification of DC energy meter
Error calculation Support automatic error calculation of upper software
Start test support
Latent test support
Ripple test support
Generate report support


2.Technical indicators


No. Name Indicator range
1 Accuracy level 0.05
2 Voltage, current, small signal amplitude accuracy Voltage: 0.02% RD + 10mV
Current: 0.05% RD+20uA
Small signal: Uo ≤ 4 mV: 0.05 % RD +10 uV;
4 mV ≤ Uo ≤ 5 V: 0.05 % RD
3 power error 0.1%
4 output phase number 1 phase voltage, 1 phase current
1 way small signal
5 gear setting voltage: 65V, 250V, 500V, 750V, 1000V
Current: 0.02A, 0.2A, 1A, 5A, 10A, 20A, 60A, 200A
Small signal: 2.5mV, 20mV, 100mV, 1V, 5V
6 Output stability Voltage: better than 0.01%, typically 0.005%
Current: better than 0.01%, typically 0.005%
Small signal: better than 0.02%
7 Output power Current: 200VA maximum, port voltage up to 2V
Voltage: up to 100VA, output current 100mA
Small signal: Uo≤1V:≤1mA
1V≤Uo≤ 5V:≤10mA
8 Ripple superposition Frequency: 20~500Hz
Ripple voltage accuracy: 20-500Hz: <0.5%
Ripple current accuracy: 20-200Hz: <1%
200-500Hz: <5%
9 Long-term stability Voltage and current: ±100PPM/year


3. Notes (Important)


l Although the device has three inspected pulse input ports, only one of the inspected tables that are not isolated for voltage and current input can be calibrated at a time.
l The voltage and current outputs of the device are isolated from each other, allowing the user to have a short contact between voltage and current during use, that is, only a single point connection of voltage and current is allowed.
l The voltage output can be as high as 1000V, which is a threat to personal safety. Please pay attention to safety.


Quality High Accuracy Electrical Calibration Equipment For For DC Energy Meter Verification for sale
Send your message to this supplier
 
*From:
*To: XL Science And Technology Co. Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You May Like
    You may also be interested in :
    Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly