Categories | Thermocouple Bare Wire |
---|---|
Brand Name: | Tankii |
Model Number: | Chromel Alumel |
Certification: | ISO9001 |
Place of Origin: | China Mainland |
MOQ: | 10kg per leg |
Price: | Negotiation |
Payment Terms: | T/T, Paypal, Western Union, MoneyGram, |
Supply Ability: | 1000Ton per year |
Delivery Time: | 5-7 days after getting the payment |
Packaging Details: | Standard exoprt package in carton box or wooden box |
Material: | Chromel alumel |
Surface: | Bright |
Diameter: | 19*0.16mm |
Wire Type: | Stranded wire |
Insulation: | Customized |
Wire class: | IEC class I , II |
Leading time: | 3 days after getting the payment |
22AWG N Type Thermocouple Wire Stranded Wire 19*0.16mm With IEC
60584 Class 1
A typical thermocouple construction consists of a pair of
dissimilar metals that are electrically joined together at the
sensing point and connected to a voltage measuring instrument at
the other end. When one junction is hotter than the other, a
thermal “electromotive” force (in millivolts) is produced that is
roughly proportional to the difference in temperature between the
hot and cold junctions.
NiCrSi thermocouple wire type N
The Type N thermocouple is composed of a nickel-14% chromium-1 1/2%
silicon (+) wire versus a nickel 4 1/2% silicon-1/10% magnesium (-)
wire. It was developed to be used under the same conditions as a
Type K. Type N should be used in oxidizing or inert atmospheres
with a service temperature range between -200°C and 1260°C (-330°F
to 2300°F). The addition of silicon and chromium makes this type of
thermocouple more resistant to Green-Rot and less drifting when
compared to a Type K. The negative element, or NN, of a Type N
thermocouple can be described by any of the following names: Nisil,
nickel-silicon.The positive element, or NP, of a Type N
thermocouple can be described by any of the following names:
Nicrosil, nickel-chromium-
silicon.
22AWG N Type Thermocouple Wire Stranded Wire 19*0.16mm With IEC
60584 Class 1
Characteristics:
The thermocouple wires have excellent performance and are
extensively used in the temperature measurement and control in
different fields, such as metallurgy, chemical industry, petroleum
industry, machinery-electric industry, energy industry, agriculture
and military industry.
Our products conform to the standards of IEC584 -1and IEC-2.
Thermocouple type and index | Measurement Range ℃ | |
Type | Index | |
| B | 600~1700 |
| R | 0~1600 |
| S | 0~1600 |
| K | -200~1300 |
| E | -200~900 |
| J | -40~750 |
| T | -200~350 |
| N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
Thermocouple | Grade | Temperature range | Allowable Tolerance /℃ |
Type B | Ⅱ | 600~1700 | ±0.25% t |
Ⅲ | 600~800 | ±4 | |
800~1700 | ±0.5%t | ||
Type R(S) | Ⅰ | 0~1100 | ±1 |
1100~1600 | ±[1+(t-1100) ×0.3%] | ||
Ⅱ | 0~600 | ±1.5 | |
600~1600 | ±0.25% t | ||
Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |
![]() |