Categories | Stator Testing Machine |
---|---|
Brand Name: | AIP |
Model Number: | AIP89** |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1 set |
Price: | Negotiable |
Payment Terms: | L/C, T/T |
Supply Ability: | 50 sets per month |
Delivery Time: | 30 working days |
Packaging Details: | wooden cases |
Hipot/surge voltage: | AC 500-5KV |
Power supply: | Customized to adapt worldwide requirements |
Test items: | Hipot, insulation resistance, surge, winding resistance and direction of rotation |
Name: | Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor |
Testing station: | Two stations |
Warranty: | 12 months |
Stator Testing Machine For Compressor Motor Stator/Refrigerator/Air Conditioner Compressor Motor
1. Product: Stator testing machine
2. Tested product: compressor motor stator
3. Stator testing machine introduction
This testing machine can be used to test the stator of compressor motor for home appliance. The AC Hipot/high voltage/dielectric strength, insulation resistance, surge/impulse/layer short, winding resistance and direction of rotation can be tested at one-stop.
The testing machine comes with two test stations to ensure the efficiency of the production. All the tests mentioned above takes less than 8 second in total for one stator. Standard equipped with the three color alarm light to indicate the machine status.
4. Technical specification
4.1 Hipot/high voltage/dielectric strength
output voltage setting range/precision | AC 500~5000V ±(1.5%×setting value+10V) |
Leakage current testing range/precision | 0.10~30.00mA ±(2%×display value+0.05mA) |
Hipot current presetting alarm range | Max: 0.10~30.00mA; Min: 0.00~30.00mA |
Hipot current/resolution | ±(2%×display value+0.05 mA);0.01 mA |
test time range/resolution | 0.5~999.9s 0.1s/step |
arc detection | 0~9 grade |
4.2 Insulation resistance
output voltage setting range/precision | DC 500V/1000V ±(1.5%×display value+10V) |
insulation resistance testing range/precision | 1~500MΩ ≤100MΩ:±(3%×display value+0.5MΩ); >100 MΩ:±(5%×display value+5MΩ) |
insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ |
test time range/resolution | 0.5~999s 0.1s/step |
4.3 Surge
output voltage setting range/precision | 500~5000V ±(3%×display value+10V) |
sampling frequency | 100MHz |
waveform comparison | area, area difference, corona, phase three waveforms will be displayed on the testing interface |
4.4 DC winding resistance
measuring range and precision | 10.0mΩ~2000Ω ±(0.3%×display value+3 words) temperature compensation can be set |
test time range/resolution | 0.5~20s 0.1s/step |
temperature compensation | Yes |
temperature probe/measuring range | DS18b20 -10.0℃~+50.0℃ |
precision | ±0.5°C(range: -10℃~+50℃) |
4.5 Direction of rotation
Rotation | CW/CCW/Still |
![]() |