Categories | Honeywell Limit Switch |
---|---|
Brand Name: | Honeywell |
Model Number: | DWR3 |
Place of Origin: | USA |
MOQ: | 1 PCS |
Price: | USD |
Payment Terms: | T/T |
Delivery Time: | 3-5 days |
Condition: | Original New |
Warranty: | 12 Months |
Shipping term: | DHL/TNT/UPS/FEDEX etc. |
Name: | Honeywell Limit Switch |
Model: | Fema DWR3 |
Feature: | Durable |
Ironman Technology Co.,LTD
Featured Brand:
● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER
● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more !
Honeywell Fema DWR3 Pressure Switch new in box
Lead time:3-5 days
New with one year warranty
Fema Pressure monitor for hot water, steam, gas, fuel (DWR)
For overpressure monitoring of steam, hot water, burnable gases,
liquid fuels.
Kind of pressure: overpressure, relative
Pressure connection: internal thread G1/4, external thread G1/2
Electrical connection: Plug DIN EN 175301
Protection class: IP54
Housing material: rugged housing of seawater resistant aluminium
die casting GD Al Si 12
Sensing element material: 1.4104 + 1.4571
Media temp.: -25...70C
Media temp. limit: temperatures up to 85 oC are allowable for short
periods. Higher temperatures are possible, provided that the limit
is safeguarded by suitable measures (e.g. water tube trap, see
Accessories for Pressure Switches / Transmitters)
Ambient temperature: -25...70C
Ambient temp. limit: at temperatures below 0 oC, ensure that no
water condensation can arise in the sensor and in the switching
device
Switch function/capacity: SPDT Microswitch 250 Vac; capacity 5 A
inductive, 8 A resistive
Mechanical lock/reset: with special function possible
Optional functions: add the type numbers below to the listed type
numbers for extra functionality as described
-213: gold-plated contacts, switching capacity: max. 24 Vdc, 100
mA, min. 5 Vdc, 2 mA. And others not available with adjustable
switching difference.
-301: terminal connection housing, IP65
-513: Gold-plated contacts, single-pole switch-over. Switching
differential permanent. IP65. Switching capacity: max. 24 Vdc, 100
mA, min. 5 Vdc, 2 mA, suitable isolating switching amplifier
necessary, degree of protection Ex-i
Certificates: TV.DWFS (SDBFS).17-281 according VdTUEV Memorandum
Pressure 100, Issue 03.2017 and DIN EN 12952-11 and DIN EN
12953-9:2007
ID 0000035004 according DIN EN 764-7:2002 and DIN EN 13611:2015-09
CE-0085CL0343 according to DIN EN 1854, Issue 01.10.2010
01 202 931-B-11-0003 according Directive 97/23 EC
SIL2 according IEC 61508-2
Fixed pressure hysteresis
Pressure adjustment range: 0.2...2.5bar
Adjustable switching differential: no
Switching differential: 0.1bar
Max. pressure: 16bar
![]() |