Categories | Glue Potting Machine |
---|---|
Certification: | CCC, FDA, RoHS, ISO, CE |
Brand Name: | D&H |
Model Number: | PGB-700 |
Place of Origin: | MADE IN CHINA |
MOQ: | 1 Unit |
Price: | USD 15000 |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 1000/Year |
Delivery Time: | 5-8 Working days |
Packaging Details: | 155X135X170 CM |
Model NO.: | PGB-700 |
Warranty: | 12 Months |
Automatic Grade: | Automatic |
Installation: | Vertical |
Driven Type: | Electric |
Transport Package: | Poly-Wood Case |
Specification: | 700x700x100 |
Trademark: | Daheng |
Origin: | China |
HS Code: | 8424899990 |
Package Size: | 100.00cm * 100.00cm * 50.00cm |
Package Gross Weight: | 100.000kg |
After-sales Service: | Provided |
Precision: | High Precision |
Condition: | New |
Samples: | 1 Piece(Min.Order) | |
Customization: | Available | Customized Request |
Shipping Cost: | about shipping cost and estimated delivery time. |
: | Initial Payment Full Payment |
Currency: | US$ |
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
AB ratio: | 100:100-100:10 adjustable |
Movement Track: | Dot/Line/Arc/Circle |
Speed: | 300mm/s (Movement speed) 1-12g/s (gluing out speed) |
Accuracy: | ±0.03mm (Repeatability) ±2% (potting) ±2% (mixing) |
Program: | 99pcs/999pcs |
Input pressure: | 0.5MPa-0.7MPa |
Viscosity: | 50cps-30000cps (Material can be heated to decrease viscosities) |
Operation Method: | Manual/Automatic |
Meter Pump: | Gear pump/Screw pump/Double cylinder plunger pump |
Flow Control: | Digital Input |
Programming method: | Teaching programming |
Automated Control system: | PLC / touch screen (programming, modification, storage, etc.) |
Glue control system: | AB glue suction valve to achieve independent operation of AB glue |
Mixed mode: | Dynamic and static optional, instant mixing, easy to clean |
Tank: | Stainless steel(40L),(25L),(10L)optional |
Power supply: | 220V/50Hz/1200W ( The power consumption without heater) |
Drops always happened when valve closed . The reason may be low concentration of glue , big air-pressure or large diameter of needles.
Narrow needles will effect the flow of the liquid and cause back pressure . It will lead to dropping when the valve closed . Too narrow needles will effect the drainage of air when valve start to work, but it can be solved if change suitable needles .
Conical needles with less back pressure and liquid flow smoothly .
It is better to drainage of the air advance or use no-foam glue or deaeration to avoid the air cause dropping after valve closed .
The problem cause mainly because of the storage flow pressure tank or air pressure is not stable.
Inlet pressure regulating table should be set lower 10-15psi than factory minimum pressure . The pressure in pressure tank should be set upper than the middle pressure of regulating table . It should be avoided to use the pressure lower than the middle pressure of regulating table .
Control pressure of rubber valve at least higher than 60psi to assured glue evenly .
We should check the glue output speed at last . The glue is uneven if the time less than 15/1000s , the output speed more longer , the glue dispensing will be more stable .
It should be changed the pipe from 1/4 to 3/8 if the flow velocity too slowly .
The pipe is the shorter the better if no requirement .
Excessive fluid pressure and short valve opening time may lead to the air infiltration liquid . We can use the conical needles and reduce fluid pressure .
This problem is caused by heavy moisture and recycle instant glue . We should make sure to use new instant glue and wash the pipes with dry . Make sure air dry and add filter between plant air pressure and valve .
Make sure to use black pipeline.
Don't add new UV glue to old UV glue in pressure tank , we should drain off the old UV glue before pouring new UV glue into pressure tank because the UV glue will produce bubble after a period of time and lead to glue dispensing unevenly .
Normally , it may cause air problem if the needle less than NO.20 . It is better to use large steel needles or conical needles to avoid to use winding needles needles
It is better to use storage pressure cylinder of methybenzene toluene to self-cleaning one time for each shift . The more frequently cleaning the better .